4S 40A BMS

4S 40A BMS

SKU: AR274 Category:

Features

  • Charging voltage: 16.8V – 18.1V
  • Continuous discharge current (upper limit): 40A

    Description Min. Typ. Max. Units
    Consuming?current 12 18 24 uA
    Overcharged?protection voltage 4.2 4.25 4.3 V
    Balanced?starting?voltage 4.17 4.2 4.23 V
    Equilibrium?current 95 100 105 mA
    Balanced?heating?power 1.56 1.72 1.91 W
    Overcharge?recovery?voltage 4.1 4.15 4.2 V
    Over-discharge?protection?voltage 2.4 2.5 2.6 V
    Overvoltage?protection?after?over-discharge?protection 2.8 3 3.2 V
    Overvoltage?protection?after?over-discharge?protection 3.2 3.5 3.8 V
    Over-discharge?recovery?voltage 2.9 3.2 3.3 V
    Conduction?internal?resistance 2.5 3 3.5 m?
    Overcurrent?protection?current?C 70 80 90 A
    Overcurrent?delay?time 100 150 200 ms
    Continuous?operating?current 0 40 40 A
    Continuous?output?power 0 672 672 W
    Ambient?temperature -40 25 85 ?C